There was a problem loading the comments.

Disk goes too far forward beyond the face of the powder measure

Support Portal  »  Knowledgebase  »  Viewing Article

  Print
Discovered on 12/14/2011, some of the Auto Disk and Pro Auto Disk Powder Measure units have left the factory without the drop tubes fully seated in the Powder Measure.

Symptom: the disk in the Auto Disk Powder Measure extends beyond the face of the powder measure (travels too far)

Fix: to correct this issue, turn your powder measure upside down and place the drop tube opening against a table edge. Drive the drop tube in using a wooden dowel and hammer or a plastic mallet.

Auto Disk Drop TubeAuto Disk Drop Tube 2

Pro Auto Disk Drop Tube 2Pro Auto Disk Powder Meausre Drop Tube

Share via

Related Articles


Self-Hosted Help Desk Software by SupportPal

Tags

© Lee Precision, Inc.